Electromagnetic Flowmeter

Submit a Quote Request with Ease

Add your desired products to the cart and submit your list for a quote—quick, easy, and without obligation. If you have any questions, please email us.

Inquiries and Support

Should you have any inquiries regarding our products or their applications, please feel free to contact us by phone. We are here to assist you.

AMC3200E Series

Datasheet

The ALIAMAG AMC3200E Series is a heat meter converter for electromagnetic flowmeters that pairs with any ALIA AMF series sensor. It offers multiple display parameters, including flow rate, energy, total flow, total energy, supply and return temperatures, diagnostics, programming, and troubleshooting. Equipped with MODBUS, Bluetooth, and BACnet protocols, it features a three-line LCD display for flow rate and totalizer. With an accuracy of ±0.2% of the reading, the converter supports bi-directional flow measurement, current, and pulse outputs. It is explosion-proof (Ex d ia [ia] q II C T6) and can be rotated in four directions for easy installation.

Technical Specifications
Excitation

DC Plused

Display

4 Lines LCD with backlight
Line 1: Date and Time
Line 2: 5 Digit flowrate, 6 Digit energy value, Error code, Supply temperature
Line 3: 9 Digit totalizer for forward flow / reverse flow, 9 Digit totalizer for heat / cold energy, Error code content, Return temperature
Line 4: Differential temperature
Unit: L/s, L/min, L/hr, m3/s, m3/min, m3/hr, mL/hr, mL/min, mL/s, kW, MW, KJ/hr, MJ/hr, GJ/hr, Mcal/hr, Kcal/hr, Cal/hr, BTU/hr

Measuring Range

Min. 0-0.15 m/s
Max. 0-15 m/s

Accuracy

+/-0.2% of reading (Velocity≥0.5 m/s)
+/-0.001 m/s (Velocity<0.5 m/s)

Repeatability

+/-0.05% of reading

Current Output

4-20 mA (Isolated)
Load: Max. 600 Ω

Pulse Output

Open collector
Rating: 3-30 VDC, 50 mA Max.

Pulse Rate

1) Scaled pulse, (L/Pulse, Other)
2) Frequency: 0-5000 Hz

Communication

Bluetooth (Apply to Android System)
RS485 (MODBUS Protocol) / BACnet

Keypad

3 External keys for programming and display control

Low Flow Cutoff

0-9.9%

Data Logger Function

99 Date / time records for alarm

Record Data

Date / time of power on/off / 99 Years flow rate / energy / temperature / total flow / total energy Record data every one hour

Damping

0.1-99.9 s

Self Diagnosis

The following error messages are displayed if failure occurs

– Temperature failure
– Temperature abnormal
– Empty pipe
– EEPROM abnormal

Data Storage

Operation parameters and totalizer figures are stored by EEPROM for more than 10 years

Cable Entry

Standard: M20 Option: 1/2" NPTF

Protection Class

IP67

Ambient Temperature

-25-65 °C

Material

Aluminum Alloy

Temperature Input

PT1000, 2 wires

Power Supply

90-260 VAC, 50/60 Hz
24 VDC +/-10% (Option)

Power Consumption

10-20 W (Dependent on sensor size)

Weight

4.5 kg

Mounting

Bracket on 2" pipe